ZENOSOFT® Software ZENO® User Menu
| C | COMMUNICATIONS MENU | |
| 1 | Baud rate for COM 1 | 300 to 19200 baud |
| 2 | Baud rate for COM 2 | 300 to 19200 baud |
| 3 | Baud rate for COM 3 | 300 to 19200 baud |
| 4 | Port type of COM 1 | RS232, RS232H (half-duplex), RADIO or TW-RADIO |
| 5 | Port type of COM 2 | RS232, RS232H, RS485, or GOES |
| 6 | Port type of COM 3 | RS232, RS232H or RS485 |
| T1-3 | Enter TERMINAL mode to COM 1,2,3 | RS232, RS232H or RS485 |
| M | MODEM MENU | |
| 1 | System modem type | 0 - no modem; 1 - phone modem |
| 2 | COM port for modem dial-out | NONE, COM1, COM2 or COM3 |
| 3 | Time between re-dial attempts | 0 to 3600 |
| 4 | Modem hang-up delay | 0 to 3600 |
| 5-8 | Telephone numbers | Any 50-character string |
| G | GOES MENU | |
| D | Run GOES DIAGNOSTICS | |
| R | RESET GOES errors | |
| I | INITIALIZE GOES radio | Set the ZENO clock to Greenwich Mean Time |
| 1 | Data Collection Platform address | 8-digit HEX value |
| 2 | Self-timed transmit channel number | 2-digit HEX value |
| 3, 4 | Self-timed transmission interval and offset | Interval must be non-zero |
| 5 | Transmission window length | Greater than zero |
| 6 | Satellite link preamble | SHORT or LONG |
| 7 | Random transmit channel number | 2-digit HEX value |
| 8 | Random transmission interval in minutes | Must be non-zero |
| 9 | Random transmission disable time | Must be non-zero |
| P | POWER CONTROL MENU | |
| 1 | COM1 PTT setup time | 0 to 1000 ms |
| 2 | COM1 switched power source | 0 - none (use fixed power) 1 - 5 V switched A 2 - 5 V switched B 3 - 12 V switched A (default) 4 - 12 V switched B 5 - 12 V switched C |
| 3 | COM2 switched power source | As COM1, with no default |
| 4 | COM3 switched power source | As COM1, with no default |
| D | DIGITAL CONTROL MENU | |
| 1 | Power-on interval | 0 to 168 hours (0 = disabled) |
| 2 | Power-on duration | 1 second to Power-on Interval |
| 3 | Start of first power-on | 1970/01/01 12:00:00 a.m. to 2030/12/31 11:59:59 p.m. |
| 4 | Control channel | 0, 18 - 23 (0 = disabled) |
| F | SYSTEM FUNCTION MENU | |
| 1 | Primary Unit/Experiment ID | 0 to 9999 |
| 2 | Secondary Unit/Experiment ID | 0 to 9999 |
| 3 | Data dump format | 1 - space delimited 2 - comma delimited 3 - match the real-time format |
| 4 | Real time output format | 0 - none 1 - ASCII 2 - formatted ASCII 3 - CCSAIL |
| 5 | Add compass to vane | 0 - no; 1 - yes |
| 6 | Compass offset | -180 to +180 |
| 7 | Barometer elevation | 0 to 5000 meters |
| S | SAMPLE PERIOD MENU | |
| 1 | Sample interval time | 1 to 86400 seconds |
| 2 | Sample duration time | 1 second to sample interval time |
| 3 | Sample time offset | 0 to sample interval time |
| D | DATA RETRIEVAL MENU | |
| A | Show records AFTER specified time | Precede by X for X-modem transfer |
| B | Show records BETWEEN specified times | Precede by X for X-modem transfer |
| Ln | Show LAST n records | Precede by X for X-modem transfer |
| * | Show all records | Precede by X for X-modem transfer |
| @n | Show n unmarked records | Precede by X for X-modem transfer |
| M | MARK recently shown data | |
| C | COMPUTE data logging capacity | |
| D | DELETE all data records | |
| N | Show NUMBER of records logged | |
| T | TEST MENU | |
| Rx,y | Display RAW data values for sensors x thru' y | Enter R to display values for all sensors |
| Sx,y | Display SCALED data values for sensors x thru' y | Enter S to display values for all sensors |
| Cx | CALIBRATE sensor number x | Administrator level password required |
| P | SDI-12 PASS-THROUGH mode | |
| Vx | VIEW process record number x | |
ZENO® Program Menu Back to ZENOSOFT® Software