ZENOSOFT® Software – ZENO® User Menu

CCOMMUNICATIONS MENU
1Baud rate for COM 1 300 to 19200 baud
2Baud rate for COM 2 300 to 19200 baud
3Baud rate for COM 3 300 to 19200 baud
4Port type of COM 1 RS232, RS232H (half-duplex), RADIO or TW-RADIO
5Port type of COM 2 RS232, RS232H, RS485, or GOES
6Port type of COM 3 RS232, RS232H or RS485
T1-3Enter TERMINAL mode to COM 1,2,3 RS232, RS232H or RS485
MMODEM MENU
1System modem type 0 - no modem; 1 - phone modem
2COM port for modem dial-out NONE, COM1, COM2 or COM3
3Time between re-dial attempts 0 to 3600
4Modem hang-up delay 0 to 3600
5-8Telephone numbers Any 50-character string
GGOES MENU
DRun GOES DIAGNOSTICS  
RRESET GOES errors  
IINITIALIZE GOES radio Set the ZENO clock to Greenwich Mean Time
1Data Collection Platform address 8-digit HEX value
2Self-timed transmit channel number 2-digit HEX value
3, 4Self-timed transmission interval and offset Interval must be non-zero
5Transmission window length Greater than zero
6Satellite link preamble SHORT or LONG
7Random transmit channel number 2-digit HEX value
8Random transmission interval in minutes Must be non-zero
9Random transmission disable time Must be non-zero
PPOWER CONTROL MENU
1COM1 PTT setup time 0 to 1000 ms
2COM1 switched power source 0 - none (use fixed power)
1 - 5 V switched A
2 - 5 V switched B
3 - 12 V switched A (default)
4 - 12 V switched B
5 - 12 V switched C
3COM2 switched power source As COM1, with no default
4COM3 switched power source As COM1, with no default
DDIGITAL CONTROL MENU
1Power-on interval 0 to 168 hours (0 = disabled)
2Power-on duration 1 second to Power-on Interval
3Start of first power-on 1970/01/01 12:00:00 a.m. to 2030/12/31 11:59:59 p.m.
4Control channel 0, 18 - 23 (0 = disabled)
FSYSTEM FUNCTION MENU
1Primary Unit/Experiment ID 0 to 9999
2Secondary Unit/Experiment ID 0 to 9999
3Data dump format 1 - space delimited
2 - comma delimited
3 - match the real-time format
4Real time output format 0 - none
1 - ASCII
2 - formatted ASCII
3 - CCSAIL
5Add compass to vane 0 - no; 1 - yes
6Compass offset -180 to +180
7Barometer elevation 0 to 5000 meters
SSAMPLE PERIOD MENU
1Sample interval time 1 to 86400 seconds
2Sample duration time 1 second to sample interval time
3Sample time offset 0 to sample interval time
DDATA RETRIEVAL MENU
AShow records AFTER specified time Precede by X for X-modem transfer
BShow records BETWEEN specified times Precede by X for X-modem transfer
LnShow LAST n records Precede by X for X-modem transfer
*Show all records Precede by X for X-modem transfer
@nShow n unmarked records Precede by X for X-modem transfer
MMARK recently shown data  
CCOMPUTE data logging capacity  
DDELETE all data records  
NShow NUMBER of records logged  
TTEST MENU
Rx,yDisplay RAW data values for sensors x thru' y Enter R to display values for all sensors
Sx,yDisplay SCALED data values for sensors x thru' y Enter S to display values for all sensors
CxCALIBRATE sensor number x Administrator level password required
PSDI-12 PASS-THROUGH mode  
VxVIEW process record number x  

ZENO® Program Menu         Back to ZENOSOFT® Software

Please contact us for complete information on Coastal's Automatic Weather Stations.